No. | Circuit board | Explanation |
|---|---|---|
1 | Out | Brownout detection: Open collector, connected to GND if supply voltage is sufficient. This output activates if the supply voltage at VIN falls below 10.0 VDC (±0.5 VDC). The earth connection is usually connected to the AUX relay's coil. If the supply voltage falls at VIN, the AUX relay activates before the other relay contacts activate unchecked due to the decreasing voltage. When the supply voltage is applied, the output does not activate until the module has fully initialised and relay contacts can no longer switch unchecked. |
2 | I- | Isolated digital input. Currently not in use. |
3 | I+ | Isolated digital input. Currently not in use. |
4 | B | Controller connection: Data Line B; connected to contact for Reader 3. |
5 | A | Controller connection: Data Line A; connected to contact for Reader 3. |
6 | C | Controller connection: Earth; connected to contact for Reader 3. |
7 | 4a | Relay 4: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
8 | 4b | Relay 4: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
9 | 3a | Relay 3: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
10 | 3b | Relay 3: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
11 | 2a | Relay 2: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
12 | 2b | Relay 2: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
13 | 1a | Relay 1: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
14 | 1b | Relay 1: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
15 | 5b | Relay 5: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
16 | 5a | Relay 5: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
17 | 6b | Relay 6: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
18 | 6a | Relay 6: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
19 | 7b | Relay 7: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
20 | 7a | Relay 7: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
21 | 8b | Relay 8: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
22 | 8a | Relay 8: Potential-free contact (NC treated as NO in software); activated depending on authorisations. |
23 | K2 | AUX relay: Potential-free contact (NO). Contact is connected with K1 (number 26) if coil is connected to power. Equipped with a detachable bridge to + (number 24) ex works. |
24 | + | VIN. Connection for power supply. Equipped with a detachable bridge to K2 (number 23) ex works. |
25 | A+ | AUX relay: Coil's plus connection. AUX relay activates if coil is connected to power. Equipped with a detachable bridge to K1 (number 26) ex works. |
26 | K1 | AUX relay: Potential-free contact (normally open contact). Contact is connected with K2 (number 23) if coil is connected to power. Equipped with a detachable bridge to A+ (number 25) ex works. |
27 | A- | AUX relay: Coil's minus connection. AUX relay activates if coil is connected to power. |
28 | - | GND. Connection for power supply. |