Technical specifications - SmartOutput module with SmartRelay 3

Housing

Material

  • Housing: Polycarbonate plastic, fibre-reinforced
  • Cover: Polycarbonate plastic

Colour

  • Housing: green similar to RAL 6021 (pale green)
  • Cover: transparent

Standard protection rating

IP20

Weight

~ 170 g (without packaging)

Installation

DIN rail (37 mm × 15 mm)

Power supply

Screw terminals

  • VIN: 12 VDC (11 VDC–15 VDC)
  • Standby current: < 120 mA
  • Max. current: < 150 mA
  • Reverse voltage protection: yes

Ambient conditions

Temperature range

  • 0 °C to +60 °C (operation)
  • 0 °C to +70 °C (in storage > 1 week)

Humidity

Max. 90%, non-condensing

Interfaces

RS485

Acts as an interface to the system controller.

  • Number of ports: 1
  • Length: ≤ 150 m, max. distance 300 m (depending on firmware and cabling)

Signal

LED

1 RGB

8 green

Relay

Quantity

8x, programmable separately from one another

Switching modes

Monoflop

Switching interval

Programmable between 0 s to 25 s (as controller).

Contact type

1x NC

Contact material

AgNi+Au

Service life (electrics)

12 VDC / 10 mA: typ. 5 × 107 switching cycles

Service life (mechanical)

Typically 100 × 106 switching cycles

Bounce time

Typically 1 ms, max. 3 ms

Vibrations

15 G for 11 ms, 6 shocks as per IEC 68-2-27; not tested for permanent operation under vibration

AUX relay switching voltage

Max. 24 V

AUX relay switching current

  • Max. 1 A permanent current
  • Max. 2 A switching current

AUX relay contact type

1x NO

Switching voltage in outputs

Max. 24 V

Switching current in outputs

Max. 200 mA

OUT switching current

Max. 1 A

OUTPUT switching voltage

Max. 24 V

OUTPUT switching power

Max. 1 VA

OUT switching behaviour for low voltage

UV < 10.5 ± 0.5V corresponds to off

Cable types

Lines with data transmission

Cat 5 or installation cable for telecommunications systems (e.g. F-YAY 2x2x0.6)

Lines with data transmission and power supply

Cat 5 or installation cable for telecommunications systems (e.g. F-YAY 2x2x0.6)

Lines for power supply only

Any line (e.g. F-YAY 2x2x0.6)

IMPORTANT

Take voltage drop into account

The resistance in copper produces a voltage drop, the size of which depends on the cable gauge, current flow and cable length. The power supply lines must be adequately dimensioned.

  1. Ensure that the cable gauge in lines is adequate for power supply. Use another suitable cable where necessary.
  2. If required, merge wire pairs to increase the cable gauge.
  3. Use a power source located closer to the SmartOutput module if needed.
  4. If possible, increase the supply voltage (observe technical specifications).

Dimensional drawings