Overview - MobileKey PIN code keypad (offline)
The PIN code keypad consists of two components:
- PIN code input field with evaluation
- Integrated transponders
If the PIN entered in the input field is recognised as correct, the input field triggers the corresponding integrated transponder.
With the PIN code keypad, you can operate all SimonsVoss locking devices (such as SmartRelays, cylinders, SmartHandles and activation units, etc.) with the PIN code keypad at any time. You can create up to three independent user groups. If you carry out a reprogramming that only affects one user group, you only have to inform this user group.
If you use SimonsVoss locking devices with ZK function (access and time zone control), you can also grant a person or user group temporary rights to the locking device. You can also log which PIN was used when to operate a locking device.
You can operate the same locking device with different User PINs. Since you give each user group a different User PIN, you can grant the user groups different access rights.
Conversely, it is not possible to control different locking devices with the same PIN code keypad via different User PINs, as the signal is sent to all locking devices simultaneously. This does not ensure that the locking device that matches the User PIN entered is addressed. In this case, the locking device is not operated although the correct User PIN has been entered.