Signalling - Programming device SmartCD2.G2

LED 1 lights up green.

USB cable connected: programming device ready for USB operation.

USB cable not connected: programming device ready for Bluetooth operation.

LED 1 flashes green.

Programming device in standby mode.

LED 2 lights up yellow.

Batteries are being charged.

LED 2 is off.

Batteries are fully charged.

The second LED only lights up when:

  • The programming device is connected to a suitable USB port for charging and
  • At least one of the batteries must be charged.

LED 3 flashes green quickly.

Communication with a SimonsVoss locking device.

LED 3 flashes green slowly.

No connection.

The third LED only lights up when wireless communication is active (e.g. programming, readout) between the programming device and a corresponding locking device.

LED 4 lights up blue.

Bluetooth active.

LED 4 is off.

Bluetooth inactive.

The fourth LED lights up while the Bluetooth interface is being used for programming, reading or resetting. It turns off automatically once the process is complete.