Programming - Digital Padlock AX (Z5.PL)
NOTE
Freely rotating active/hybrid Digital Cylinder AX only with shortened range
With freely rotating cylinders, the reader knobs may not have sufficient clearance at low cylinder lengths. Due to the range of the active technology, the radio signal can also be unintentionally received by the second reader knob.
- Program freely rotating cylinders with the SmartStick AX or the SmartCD.MP.
- Ensure that the short range is selected during programming (standard setting for cylinders factory- supplied as freely rotating).
First transponder activation rejected after initial programming of AX products
If a transponder is the first identification medium to be activated after initial programming, the transponder can be rejected once and synchronised with the locking device in the background. Transponders will then function as normal.
- LSM software version 3.5 or higher installed.
- LSM open.
- SmartStick AX, SmartCD.MP or SmartCD.G2 connected (recommended: SmartStick AX).
- Select the locking system that you require. Use the ... button to open the locking system properties and use the
and
buttons to select the required lock system. - Click on the
button to add a new locking device. - The New lock window will open.
- Open the drop-down menu.
- Select the area.
- Open the drop-down menu .
- Select the entry AX cylinder.
- Complete the rest of the form.
- Click on the Save & next button.
- Locking device has been added.
- Click on the Exit button.
- Window closes.
- Select the entry for the AX locking cylinder in the matrix.
- Position your programming device.
NOTE
Duration of initial programming
A large amount of data is transferred during initial programming. The data transfer speed is significantly higher with a SmartStick AX or a SmartCD.MP (and the programming time is therefore shorter).
- If possible, use a SmartStick AX or a SmartCD.MP for initial programming.
- Open the context menu by right-clicking on the AX locking cylinder entry in the matrix.
- Select the item.
- Open the drop-down menu .
- Select the entry Card reader (SmartCD MP) or SmartCD.
- Click on the Programming button.
NOTE
Programming with SmartStick AX
The SmartStick AX BLE interface has a wide range and can reach several locking devices at the same time. This is why the SmartStick AX first needs to know which locking device to programme.
- Tap the locking device to be programmed immediately after starting programming with the SmartStick AX.
- Programming launches.
- Wait for programming to complete.
- AX locking cylinder is programmed.