Wiring with the integrator system - SmartIntego specifications

Once you have set up the SmartIntego system, you must then connect it to the integrator system.

IMPORTANT

Communication error due to simultaneous connection to integrator system and configuration device

If you connect the RS-485 bus to the integrator system and the configuration device at the same time, both devices will attempt to communicate with the routers (SI.GN.CR) at the same time. This leads to conflicts and communication errors.

  1. Do not connect the integrator system until you have disconnected the configuration device from the RS-485 bus.
  2. Only connect the configuration device after you have disconnected the integrator system from the RS-485 bus.
  1. Undo the connection to the configuration device.
  2. Connect the integrator system.

You can connect the integrator system as shown, regardless of the wiring of the rest of the RS-485 bus.