Wiring with the configuration device - SmartIntego specifications

If you are setting up the system for the first time or making changes to the configuration, you must connect the configuration device to the RS-485 bus.

IMPORTANT

Communication error due to simultaneous connection to integrator system and configuration device

If you connect the RS-485 bus to the integrator system and the configuration device at the same time, both devices will attempt to communicate with the routers (SI.GN.CR) at the same time. This leads to conflicts and communication errors.

  1. Do not connect the integrator system until you have disconnected the configuration device from the RS-485 bus.
  2. Only connect the configuration device after you have disconnected the integrator system from the RS-485 bus.

NOTE

notice

No connection during configuration changes

If you want to change the configuration of the SmartIntego components, you have to disconnect the integrator's system from the RS-485-bus first. As long as the integrator's system is disconnected from the RS-485-bus, the routers (SI.GN.CR) aren't connected to the integrator's system. As long as this is the case, SmartIntego locks are working offline with a previously configured whitelist only.

You can connect the configuration device as shown, regardless of the wiring of the remaining RS-485 bus. Then connect the configuration device to the SmartIntego Manager via the network interface in order to perform the initial setup or change the configuration.