Signals - MobileKey PIN code keyboard online
LED colour | LED flashing | Buzzer | Event | Explanation |
|---|---|---|---|---|
Red | 8x | 4 x | Power-on reset | Reset after battery replacement – batteries not OK |
1x | 1x | Error | Error occurred | |
User PIN length incorrect | Length of the User PIN entered not correct | |||
User PIN not received | Entered User PIN not received by SmartBridge | |||
Orange | 3x | 3x | Abort | Current action has been cancelled |
4 x | 4 x | Power-on reset | Reset after battery replacement in operating mode – batteries OK | |
Green | 2x | 2x | Master PIN changed | Master PIN successfully changed |
PIN length changed | Length of the User PIN successfully changed | |||
User PIN received | Entered User PIN received by SmartBridge | |||
1x | 1x | User PIN length correct | Length of the User PIN entered correct |
LED colour | LED flashing | Buzzer | Event | Explanation |
|---|---|---|---|---|
Red | 4 x | 4 x | Battery Warning 2 | Battery very low |
Orange | 4 x | 4 x | Battery Warning 1 | Low battery |
Green | 3x | 3x | Full capacity | Batteries fully charged |
1x | 1x | Battery "OK" | Batteries OK |