LSM Terminalserver + ONLINE - Connections and ports
Local programming of SimonsVoss components is only possible with an additional device (USB Ethernet adapter).
Application | Port | Connection |
|---|---|---|
Configuration of WaveNet components via WaveNet Manager from the client | TCP 2101 | client/Terminal → WaveNet |
SV CommNode server to WaveNet | TCP 2101 | server → WaveNet |
WaveNet to SV CommNode server | TCP 2101 | WaveNet → server |
Advantage Database server and SV CommNode server to LSM-GUI | TCP 6000-6100 | server → client/Terminal |
LSM-GUI to SV CommNode server | TCP 6000-6100 | client/Terminal → server |
Advantage Database server to SV CommNode-Agent | TCP 6000-6100 | server → Fat client |
SV CommNode-Agent to Advantage Database server | TCP 6000-6100 | Fat client → server |
LSM-GUI to Advantage Database server | UDP 6262 | client/Terminal → server |
Bidirectional DNS resolution is required for communication between LSM GUI and SV CommNode server and vice versa or between LSM GUI and SV CommNode agent and vice versa.