LSM Terminalserver + ONLINE - Connections and ports

Local programming of SimonsVoss components is only possible with an additional device (USB Ethernet adapter).

Port description

Application

Port

Connection

Configuration of WaveNet components via WaveNet Manager from the client

TCP 2101

client/Terminal WaveNet

SV CommNode server to WaveNet

TCP 2101

server WaveNet

WaveNet to SV CommNode server

TCP 2101

WaveNet server

Advantage Database server and SV CommNode server to LSM-GUI

TCP 6000-6100

server client/Terminal

LSM-GUI to SV CommNode server

TCP 6000-6100

client/Terminal server

Advantage Database server to SV CommNode-Agent

TCP 6000-6100

server Fat client

SV CommNode-Agent to Advantage Database server

TCP 6000-6100

Fat client server

LSM-GUI to Advantage Database server

UDP 6262

client/Terminal server

Bidirectional DNS resolution is required for communication between LSM GUI and SV CommNode server and vice versa or between LSM GUI and SV CommNode agent and vice versa.